Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Ophthalmol Pract Res ; 3(3): 134-140, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37846363

RESUMO

Background: To report the clinical consequences and laboratory characteristics of late postoperative opacification of a hydrophilic acrylic intraocular lens (US-860UV IOL) as well as the prognosis of IOL replacement. Methods: Forty medical records (42 eyes) of patients with US-860UV IOL opacification reporting decreased or lost vision who underwent IOL explantation between 2017 and 2019 were reviewed. Explanted IOLs were analyzed by slit-lamp examination, confocal microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) at the Shandong Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University, and Qingdao University of Science and Technology, Qingdao, China. Results: The mean age of the 40 patients was 74.83 â€‹± â€‹7.57 (63-92) years. The mean interval between cataract surgery and diagnosis of opacification was 32.38 â€‹± â€‹8.76 (17-48) months. Systemic diseases were found without statistical correlations, the most frequent being arterial hypertension, coronary heart disease, and diabetes mellitus. Visual acuity improved from 1.42 â€‹± â€‹1.03 to 0.31 â€‹± â€‹0.16 (logMAR) after IOL replacement. SEM, EDS and alizarin red staining showed uniformly distributed, diffuse, milk-white opacification, with calcium and phosphorus deposits on the optic and haptic surfaces that could be dissolved in 1% HCl. Conclusions: Calcium and phosphorus deposition was the main cause of hydrophilic acrylic US-860UV IOL opacification. IOL replacement can safely and effectively improve the visual acuity of patients.

2.
Front Med (Lausanne) ; 9: 873684, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35463016

RESUMO

Objective: To compare opacity characteristics of US-860 UV and L-312 IOL, and report the phenomenon of glistenings in hydrophobic-hydrophilic acrylic IOLs. Setting: Qingdao Eye Hospital. Design: Experimental study. Methods: Four medical records (4 eyes) of patients with L-312 or US-860 UV IOL opacification reporting decreased or lost vision who underwent IOL explanation between 2019 and 2021 were reviewed. Explanted IOLs were analyzed by slit-lamp examination, confocal microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) at Qingdao Eye Hospital and Qingdao university of science and technology. Results: The 4 explanted IOLs were represented by 2 hydrophilic acrylic designs. The preoperative mean corrected distance visual acuity changed from 1.84 ± 1.09 logarithm of the minimum angle of resolution (log MAR) to 0.20 ± 0.03 log MAR postoperatively except case 3. The mean interval of the L-312 IOL was 56.67 ± 14.19 months (range 44 to 72 months), and the interval of the US-860 UV IOL was 27 months. Morphological findings were surface, subsurface calcifications of the US-860 UV IOL material, and the optical region of L-312 IOLs are teeming with a great number of vacuoles by light microscope, scanning electron microscope and Energy Dispersive X-ray Spectral. Conclusion: The cause of US-860 UV opacification was primary calcification, and vacuoles resulted in L-312 IOL opacification.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...